184_projects:austin_snafu_24

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
184_projects:austin_snafu_24 [2024/03/11 21:12] tdeyoung184_projects:austin_snafu_24 [2024/03/11 21:19] (current) tdeyoung
Line 10: Line 10:
 With your help, the FTOE staff have repaired the damage and are almost ready to restart the hawkion accelerator.  However, they had to cut the lab systems off from Lakeview completely to ensure Manny can't hack in again and do more damage.  The onsite backup generators provide enough power for the lab, but when the FTOE staff tried to power up the control systems they discovered that some critical circuit boards got fried during the emergency.  As a result, you need to create a new circuit that will allow you to provide different amounts of energy to various important systems. With your help, the FTOE staff have repaired the damage and are almost ready to restart the hawkion accelerator.  However, they had to cut the lab systems off from Lakeview completely to ensure Manny can't hack in again and do more damage.  The onsite backup generators provide enough power for the lab, but when the FTOE staff tried to power up the control systems they discovered that some critical circuit boards got fried during the emergency.  As a result, you need to create a new circuit that will allow you to provide different amounts of energy to various important systems.
  
-The hawkion generator consists of an initiator beam and a set of focusing magnets, which have a total resistance of 65 $\Omega$.+The hawkion generator has a total resistance of 65 $\Omega$, and includes an initiator beam and a set of focusing magnets.
 The focusing magnets require a short burst of 200 J to power-up. The focusing magnets require a short burst of 200 J to power-up.
 The initiator beam requires a short burst of 300 J to power-up. The initiator beam requires a short burst of 300 J to power-up.
Line 16: Line 16:
 You need to be able to deliver different amounts of power to the hawkion generator; however, you are not sure that the 100 V primary power supply in the particle generator will be sufficient to power these systems. You manage to find some additional batteries (three 10 V batteries from the supply room) to use if you need them.  You need to be able to deliver different amounts of power to the hawkion generator; however, you are not sure that the 100 V primary power supply in the particle generator will be sufficient to power these systems. You manage to find some additional batteries (three 10 V batteries from the supply room) to use if you need them. 
  
-You also have several 0.125F capacitors and resistors (1 $\Omega$, 5 $\Omega$, 10 $\Omega$, 50 $\Omega$, 100 $\Omega$) on hand. +You also have several 0.125F capacitors and a variety of resistors (1 $\Omega$, 5 $\Omega$, 10 $\Omega$, 50 $\Omega$, 100 $\Omega$) on hand. 
 You also have access to multiple switches that can be used to open and close parts of the circuit you are designing.   You also have access to multiple switches that can be used to open and close parts of the circuit you are designing.  
  
  • 184_projects/austin_snafu_24.1710191554.txt.gz
  • Last modified: 2024/03/11 21:12
  • by tdeyoung